With a zero ozone depletion potential (ODP), a global warming potential (GWP) of , and an atmospheric lifetime (ALT) of 31 + years.
If you are looking for more details, kindly visit TYHJ.
By using its tried and trusted range of 25 bar equipment, Kidde Fire Protection can offer a cost-effective fire extinguishing system.
A wide range of container sizes from 5 to 368 litres is available, offering a choice of fill capacities to meet specific requirements and ensure maximum economy in installation. Each container is manufactured from high strength alloy steel and both TPED and DOT are available. FM200® discharges as a colourless gas at standard conditions, exhibiting a boiling point of -16.4°C. Electrically non-conductive and non-corrosive gas.
Small and large-scale tests have proven that FM200® agent extinguishes fire quickly, before any serious damage occurs. Achieved by reaching the extinguishing concentration in less than ten seconds, being effective on a wide range of Class A, Class B and fires involving energised electrical equipment.
1. Product Description
FM-200 / Hfc -227ea
FM-200 is an odorless, colorless, liquefied compressed gas. It is stored as a liquid and dispensed into the hazard as a colorless, electrically non-conductive vapor that is clear and does not obscure vision. It leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration. FM-200 extinguishes a fire by a combination of chemical and physical mechanisms.
FM-200 provides excellent fire protection in a wide range of applications from sensitive electrical equipment to industrial applications using flammable liquids. FM-200 agent is used in total flooding fire suppression systems.
FM-200 does not work by displacing oxygen and is safe for use in occupied spaces without fear of oxygen deprivation.
Components of Pipe Network FM200 Fire Suppression Systems
1. Storage cylinder: Cylinder, container valve (with pilot valve, pressure indicator), dip tube, etc.
2. Liquid check valve: Assure one way flow of fire suppression agent, to prevent backflow.
3. High pressure hose: Connect cylinder valve and liquid check valve .
4. Safety valve: Fitted on the manifold to relieve higher pressure.
5. Selection valve: Guide fire suppression agent into different distribution pipe network.
6. Starting gas bottle: Bottle, container valve, electromagnetic drive device, pressure gauge.
7. Gas check valve: Assure one way flow of starting gas, to prevent backflow.
Contact us to discuss your requirements of FM200 Specialty Gas factory. Our experienced sales team can help you identify the options that best suit your needs.
8. Low leakage high sealing valve: For accumulated starting gas release so to avoid malfunction of system.
9. Discharge Nozzle: Fitted at the end of pipe network to discharge fire suppressing agent.
10. Control System: Control panel, smoke and heat detector, fire alarm, discharge indicator light, etc.
Advantage
* Very swift fire suppression. Reach extinguishing level '10s.
* Safe to people. People is safe when exposed at the FM200 gas discharge level.
* Low extinguishing concentration. Nearly no obscure to vision in person evacuation.
* Easy to clean. No residue left, and minimize damage to sensitive equipment.
* Environment friendly. Zero ozone depletion potential and zero global warming potential.
* Simple installation, with small storage space.
2. Working Principle
When the control mode selection key on the automatic fire alarm and fire extinguishing controller is set to the "auto"position, the fire extinguishing system is under automatic control. When a fire occurs in the protection area, the temperature and smoke detectors will send out a fire signal through the automatic fire alarm and extinguishing control After the logic analysis of the device, it sends out a combined sound and light alarm signal, and sends out a linkage command at the same time to close the linkage device. After a delay, a fire extinguishing command is issued, the starting valve is opened to release the starting gas, and the starting gas is opened through the control gas pipeline valves and container valves release the fire extinguishing agent and implement fire extinguishing.
3. Product Parameters
ItemModelVolume x QtyCapacity (FM200)Working Pressure (20ºC)Max Working Pressure (50ºC)Activate voltage/ currentOperating Temperature Range1GMQ4.2/90N-PRI90X1'100.8kg4.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC2GMQ4.2/120N-PRI120X1'134.4kg4.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC3GMQ4.2/150N-PRI150X1'168kg4.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC4GMQ4.2/180N-PRI180X1'201.6kg4.2Mpa5.6MpaDC24 V/1.2A0ºC-50ºC4. Work Shop
5. Product Application
MODEL ONE WITH ZONE VALVE
MODEL TWO WITHOUT ZONE VALVE' Bank vaults
' Libraries
' Book stores
' Electronic data processing
' exchanges
' Communication centers ' Transformer and switch room
' Control rooms
' Test laboratories
' Flammable liquid storage
6. Packing&Shipping
9. Contact ways